Skip to main content
Home

Search form

  • News
  • Meetings
  • Visitors
    • Hospitality Survey
  • Services
    • Animal Control and Licences
    • Building Permits & Inspections
      • When is a Building Permit Required
      • Application Forms and Process
      • Order of Inspections
      • Other Agencies Involved
    • Burning
    • Bylaw Enforcement and Adjudication
    • Cemetery
    • Emergency
    • Facilities and Equipment
    • Garbage & Recycling
    • Grants
    • Planning & Development
    • Snow Removal and Road Maintenance
    • Water & Sewer
  • Village Office
    • COVID-19
    • Newsletters
      • Register Newsletter
    • Bylaws
    • Contact Us
    • Documents & Publications
    • Finance
      • Budget
      • Grants
      • Permissive Tax Exemptions
      • Public Documents
      • Tax Sale
      • Taxes
      • Utilities
    • Job Postings
    • Mayor and Council
      • Agendas and Minutes
      • Appear before Council
      • Elections
      • Meet your Council
    • Reports
    • Village Staff
    • Tourism Committee
    • Official Community Plan and Zoning Bylaw Update
  • Business
    • Business Licences
    • Chamber of Commerce
    • Community Profile & Business Guide
    • Economic Development
    • Love Valemount
    • Bid Contract
  • Community Life
    • Child Care
    • Churches
    • Community Forest
    • Community Sustainability
    • Education & Training
    • Valemount College
    • Health Services
    • History & Heritage
    • Library
    • Robson Valley Community Services
    • Trails & Parks

Building Permits & Inspections

  • When is a Building Permit Required
  • Application Forms and Process
  • Order of Inspections
  • Other Agencies Involved

You are here

Home » Services » Building Permits & Inspections

Order of Inspections

Inspections must be completed at varying stages during the project.  A typical inspection schedule is as follows:

Building Construction or Alteration Inspection Schedule

1. Footings When footing forms are complete, prior to pouring concrete.
2. Foundation When foundation wall forms are complete, prior to pouring.  If required, submit registered professional's letters of assurance prior to framing.
3. Backfill When the perimeter drain rock, drain tiles, foundation insulation (if applicable) and damp proofing is completed, prior to backfilling.  The survey (if required) for the foundation location is required prior to approval of Backfill.
4. Rough-in Plumbing When rough-in plumbing is completed prior to covering.  Water or air test must be visually confirmed by Building Official.  This can be completed in two inspections; Plumbing under the slab and above ground.
5. Municipal Service Connection When sewer, water and storm lines are installed and connected to the municipal system, prior to backfilling or covering.
6. Soil Gas After the soil gas control is installed
7. Pre-slab Prior to pouring concrete floor slab. Air barrier system and insulation must be installed where applicable.
8. Framing When framing, exterior sheathing, fire stopping, bracing, plumbing, HVAC and electrical are completed and prior to any interior and exterior finish being applied.  The Village of Valemount - reviewed/stamped drawings, truss/beam details and mechanical ventilation checklist must be on site.
9. Masonry Fireplace When masonry fireplace is constructed to the smoke chamber and again when the chimney is complete prior to interior or exterior finish.
10. Chimney When the chimney is installed prior to interior or exterior finish
11. Insulation When insulation and vapour barrier are completed, prior to installing drywall or other finish.
12. Solid Fuel Burning Appliance When the solid fuel burning appliance is installed but prior to covering up
13. Occupancy When building has received all applicable inspections and meets all health and safety requirements.  If registered professionals letters of assurance are required, no occupancy will be granted until the letters of assurance have been received. If applicable, final sewage approval from Northern Health Authority is required prior to occupancy.
14. Final When building is completed.

 

Manufactured Home Inspection Schedule

Footing Foundation When excavation is complete, prior to pouring concrete.
Occupancy Final

When the following are complete:

·        Ground cover is installed under home

·        Home anchored to foundation

·        Skirting is installed with ventilation and access door

·        Landing and stairs are installed at every exit door

       ·        Final grade of property to slope away from home

 